Chinese dental n type autoclave for dental clinic

n type autoclave is a type of sterilization device commonly used in medical and laboratory settings. Autoclaves are used to sterilize equipment and supplies by subjecting them to high-pressure steam at elevated temperatures. Class N autoclaves are equipped with various safety features to prevent accidents and ensure proper operation. These may include pressure and temperature sensors, automatic shut-off mechanisms, door interlocks, and alarms for detecting abnormalities.

Product Description

Volume 18L/23L
rated working pressure 0.22 MPa.
rated voltage AC220V + 22V, 50 + 1Hz
input power ≤ 1600VA
sterilization temperature 121 /134℃
the volume of the water tank about 1 liter
the normal use of the environment Humidity ≤85%
Air pressure 70kPa – 106kPa
Temperature 5 ~ 40℃
Noise <70db

Class N autoclaves comply with international standards and regulations for sterilization efficacy and safety. They are designed to meet the requirements of EN 13060 and other relevant standards.

Chamber Size

Class N autoclaves are available in various chamber sizes to accommodate different loads. Typical chamber sizes range from small tabletop units to large floor-standing models.

Sterilization Temperature

Class N autoclaves typically operate at temperatures ranging from 121°C to 134°C (250°F to 273°F). These temperatures are sufficient to achieve sterilization according to recommended guidelines.

Sterilization Time

The sterilization cycle time can vary depending on the load size, type of materials being sterilized, and the specific autoclave model. Standard cycles usually range from 15 to 30 minutes, with additional time for heating up and cooling down.

Sterilization Pressure

Class N autoclaves typically operate at a pressure of around 1.1 to 2.1 bar (15 to 30 psi) during the sterilization process. This pressure is necessary to maintain the steam at the required temperature for effective sterilization.

Control System

Class N autoclaves are equipped with control systems that allow for precise monitoring and adjustment of sterilization parameters such as temperature, pressure, and cycle time. Some models may feature advanced touchscreen interfaces for user-friendly operation.

Safety Features

Class N autoclaves include various safety features to prevent accidents and ensure proper operation. These may include pressure and temperature sensors, automatic shut-off mechanisms, door interlocks, and alarms for detecting abnormalities.

Construction Material

Autoclaves are typically constructed from stainless steel for durability and resistance to corrosion. The chamber and door seals are designed to maintain pressure and prevent steam leakage during the sterilization process.

Water Supply

Class N autoclaves require a water supply for generating steam. Some models feature built-in water reservoirs, while others may need to be connected to an external water source.

Power Requirements

Class N autoclaves operate on electrical power and may require single-phase or three-phase power depending on the model and size. The power requirements vary depending on factors such as chamber size and heating capacity.